WELDED TITANIUM METAL FRAME FOR PORCELAIN APPLICATION
|
|
STEP 1 - Male patient requiring implant supported
bridges 21.11.12. and 41.31.32.33.
|
|
STEP 2 - Titanium direct to fixture.
Cylinders are placed on fixture.
|
|
|
STEP 3 - Titanium jig is placed over cylinders.
|
|
STEP 4 - Cylinder and jig are joined with GC resin.
|
|
|
STEP 5 - Cylinders are shaped and welded to a
titanium plate and shaped to form a frame
to receive porcelain.
|
|
STEP 6 - Opaqued frame.
|
|
|
STEP 7 - Finished implant bridge using Noritake
porcelain.
|
|
STEP 8 - Finished bridge on index model.
|
|
|
STEP 9 - Finished lower bridge with pink porcelain in place.
|
|
STEP 10 - Upper and lower bridges in place.
|
|